SmartgridOne logo
SmartgridOne logo
Accessories
AppCertificates
Configuration from A to Z
Control response timeController
Customer Specific
Devices
Boiler
Cloud
Energy Meter
Ev Charging Station
Gas Meter
Heat Pump
New integrations
Plc
Pv Hybrid And Battery Inverters
a-TroniXABB, FIMERADS-TecAforeAlphaESSAmpowrAngileAnklous PV, Hybrid and Battery InvertersAPsystemsAteps Battery
Autarco
BeauventC-BatteryCellpowerChisageDanfossDeltaDET Power PV, Hybrid and Battery InvertersDEYEDiehl-AkoDMEGC InvertersDynessDysun EnergyEcosourcenEenovanceElecnovaEnbrilionEnergreenEnerlutionEnjoyPowersEnphaseEP EquipmentESY InvertersEVEFortona
Foxess
FraxFroniusGoodWeGotionGreener / Alfen
Growatt
HiteHithium
Huawei
Hypontech
Hyxipower
iWellJinkoKacoKehuaKostal
Kstar
MarstekMastervoltMidTeQMotomaOctave EnergyOmniPowerPixiiPower-SonicPoweroadPylontechRefurbRegitecRenonRitarSAJSchneider SunEzySchucoSCUSE2200H till SE6000HSessySigenergySinexcel
Sma
Socomec
Sofar
HYD 3000…6000-ESPowerMagicTL-G3 and TLM/X-G3 Series
Solaredge
SolarlogSolarMaxSolarwattSolaxSolinteg
Solis
Solplanet
Sungrow
SunwaytechSunwoda
Sunwoda
Sus-PowerTeclomanTeploreTesvoltVaconVictronVolstoraWattsNextWeihengXantrexZendure SolarFlowZetaraZeversolar
Switched Loads
Water Meter
External Signals
InstallationLicenseNetworkQuick StartSafety, maintenance and legal noticesSpecificationsStatus LEDs
Toolbox
Troubleshooting
Video tutorialsWiring & connectivity guidelines
DevicesPv Hybrid And Battery InvertersSofar

TODO: It looks like this is valid for more inverters?

logo

Sofar TL-G3 and TLM/X-G3 Series Inverters

Supported Devices

Device TypeModbus TCP (Ethernet)RS485Curtailment
...✅✅✅
Warning
Warning
  • Most of the devices can communicate using modbus TCP. This is not valid for the series "SOFAR 1...40KTL"
  • Some inverters require specific firmware that is limited to certain distributors. Consult your distributor in case of doubt.
Image

Wiring

Ethernet

Connect the inverter to your internet network using the "SOFAR SOLAR ETHERNET STICK LSE3".

For correct ethernet wiring: Follow the the guidelines for ethernet wiring.

RS485

...TL-G3 & G1 & G2

Info
RS485 Wiring
  • For correct RS485 wiring: Follow the guidelines for RS485 wiring.
  • If the wiring shown in the table below is incorrect, please let us know.
  • There is no general consensus in the industry about the usage of A and B for the RS485 polarity, so it may be counterintuitive and opposite of what you might expect for some devices.
DeviceSmartgridOne Controller model OM1SmartgridOne Controller model IG8RS485-USB converterRS485-Ethernet converter
RS485s TR+RS485 ARS485_POSRS485 ATX+
RS485s TR-RS485 BRS485_NEGRS485 BTX-
N/ARS GNDGNDNot availableG
Image

...TLX & TLM

Info
RS485 Wiring
  • For correct RS485 wiring: Follow the guidelines for RS485 wiring.
  • If the wiring shown in the table below is incorrect, please let us know.
  • There is no general consensus in the industry about the usage of A and B for the RS485 polarity, so it may be counterintuitive and opposite of what you might expect for some devices.
DeviceSmartgridOne Controller model OM1SmartgridOne Controller model IG8RS485-USB converterRS485-Ethernet converter
RS485s TR+ (pin 1)RS485 ARS485_POSRS485 ATX+
RS485s TR- (pin 3)RS485 BRS485_NEGRS485 BTX-
N/ARS GNDGNDNot availableG
Image

Configuration

RS485

Warning
NOTE: RS485 Device Addresses
  • You MUST give each device on the RS485 bus a unique address. Check the manual of the device on how to do this.
  • Use lower addresses first (1, 2, ...) because the SmartgridOne Controller will find them faster!
  • For each device, it is generally recommended to stick with the factory default baud rate, parity, and stop bits. The SmartgridOne Controller will scan on those first.

External inverter control must be activated in the configuration menu of the inverter via the LCD screen.

  1. Click shortly on the button down.
  2. You'll see "1. Enter settings", press button down for 2 seconds to enter the settings.
  3. Go through the settings until you see:
    • Modbus Address or
    • Set ComProtocol
  4. Press button down for 2 seconds to set the address.
  5. Set the Address to the wanted value.

PowerMagic

Previous Page

Solaredge

Next Page

On this page

Sofar TL-G3 and TLM/X-G3 Series InvertersSupported DevicesWiringEthernetRS485...TL-G3 & G1 & G2...TLX & TLMConfigurationRS485