SmartgridOne logo
SmartgridOne logo
Accessories
AppCertificates
Configuration from A to Z
Control response timeController
Customer Specific
Devices
Boiler
Cloud
Energy Meter
Ev Charging Station
Gas Meter
Heat Pump
New integrations
Plc
Pv Hybrid And Battery Inverters
a-TroniXABB, FIMERADS-TecAforeAlphaESSAmpowrAngileAnklous PV, Hybrid and Battery InvertersAPsystemsAteps Battery
Autarco
BeauventC-BatteryCellpowerChisageDanfossDeltaDET Power PV, Hybrid and Battery InvertersDEYEDiehl-AkoDMEGC InvertersDynessDysun EnergyEcosourcenEenovanceElecnovaEnbrilionEnergreenEnerlutionEnjoyPowersEnphaseEP EquipmentESY InvertersEVEFortona
Foxess
FraxFroniusGoodWeGotionGreener / Alfen
Growatt
HiteHithium
Huawei
Hypontech
Hyxipower
iWellJinkoKacoKehuaKostal
Kstar
MarstekMastervoltMidTeQMotomaOctave EnergyOmniPowerPixiiPower-SonicPoweroadPylontechRefurbRegitecRenonRitarSAJSchneider SunEzySchucoSCUSE2200H till SE6000HSessySigenergySinexcel
Sma
Socomec
Sofar
Solaredge
SolarlogSolarMaxSolarwattSolaxSolinteg
Solis
Solis Grid-tied Inverters
Solis Hybrid Inverters
3t10K-HVES-G5 WiringS-Series-Hybrid
Solplanet
Sungrow
SunwaytechSunwoda
Sunwoda
Sus-PowerTeclomanTeploreTesvoltVaconVictronVolstoraWattsNextWeihengXantrexZendure SolarFlowZetaraZeversolar
Switched Loads
Water Meter
External Signals
InstallationLicenseNetworkQuick StartSafety, maintenance and legal noticesSpecificationsStatus LEDs
Toolbox
Troubleshooting
Video tutorialsWiring & connectivity guidelines
DevicesPv Hybrid And Battery InvertersSolis
logo

Solis Hybrid Inverters

Supported Devices

Image
Device TypeModbus TCP (Ethernet)RS485Curtailment
Solis 3t10K HVES G5experimental✅✅
Solis S5-EH1P(3-6)K-L✅ (only with Solis data logger)
Solis S5-EH1P(8-10)K-L-PLUS
Solis S5-EA1P3K-L
Solis S6-EH3P(8-15)K02-NV-YD-L
Solis S6-EH3P(5-10)K-H-EU
Solis S6-EH3P(5-10)K2-H
Solis S6-EH3P(12-20)K-H
Solis S6-EA1P(3.6-6)K-L
Solis S6-EO1P(4-5)K-48-EU
Solis S6-EH3P(30-50)K-H
Note
Note

Currently, only the connection via RS485 has been tested, but you may also be able to run the inverter via Ethernet.

Control Features

Caution
Caution

Solis Inverter Firmware Ensure that you have the latest firmware installed on your Solis inverter. The functionality of external control features like battery control and curtailment is dependent on the firmware version.

The setup of your Solis is an important factor in which EMS-features supported:

Mermaid chart placeholder

Curtailment is now supported for Solis hybrid inverters. The latest firmware version by Solis includes curtailment registers that allow external control of the inverter's output power without writing to the flash memory.

Wiring (RS485)

The wiring between the SmartgridOne Controller and the Solis can be done with the following guides:

ModelPage
3t10K HVES G5Wiring configuration for 3t10K HVES G5
S5-EH1P(3-6)K-LWiring configuration for S5/S6 Series
S5-EH1P(8-10)K-L-PLUS
S5-EA1P3K-L
S6-EH3P(8-15)K02-NV-YD-L
S6-EH3P(5-10)K-H-EU
S6-EH3P(5-10)K2-H
S6-EH3P(12-20)K-H
S6-EA1P(3.6-6)K-L
S6-EO1P(4-5)K-48-EU
S6-EH3P(30-50)K-H

If your model is not listed, we refer to the manual of the Solis inverter. It should always include a section on how to wire a rs485 communication with external EMS-systems.