Onduleurs Delta
Appareils pris en charge
| Device Type | Variants | Modbus TCP (Ethernet) | RS485 | Curtailment |
|---|---|---|---|---|
| Delta RPI | M6/M8/M10/M12/M15A/M20A/M30 | ❌ | ✅ | ✅ |
| H3/H5/H3A/H4A/H5A (not tested) | ||||
| M6A/M8A/M10A/M50A/M30A (not tested) |
Câblage
Le SmartgridOne Controller et les onduleurs Delta communiquent via RS485.
RS485

| Paramètre | options |
|---|---|
| Débit en bauds | 2400 / 4800 / 9600 / 19200 (par défaut) / 38400 |
| Bits de données | 8 |
| Parité | Aucune |
| Bits d’arrêt | 1 |
Configuration
Avertissement
NOTE: RS485 Device Addresses
- You MUST give each device on the RS485 bus a unique address. Check the manual of the device on how to do this.
- Use lower addresses first (1, 2, ...) because the SmartgridOne Controller will find them faster!
- For each device, it is generally recommended to stick with the factory default baud rate, parity, and stop bits. The SmartgridOne Controller will scan on those first.
Last updated December 10, 2025Edit this page