SmartgridOne logo
SmartgridOne logo
Accessori
AppAvvertenze di sicurezza, manutenzione e legali
Cassetta degli attrezzi
Certificati
Configurazione dalla A alla Z
Controlla il tempo di rispostaControllore
Dispositivi
Caldaia
Carichi commutati
Contatore del gas
Contatore dell'acqua
Contatore Energetico
Inverter ibridi Pv e per batterie
a-TroniXABB, FIMERADS-TecAforeAlphaESSAmpowrAngileAPsystemsAttrezzatura EP
Autarco
Batteria AtepsBeauventC-BatteryCellpowerChisageDanfossDeltaDET Power Inverter Fotovoltaici, Ibridi e a BatteriaDEYEDiehl-AkoDynessDysun EnergyEcosourcenEenovanceElecnovaEnbrilionEnergreenEnerlutionEnjoyPowersEnphaseFortona
Foxess
FraxFroniusGoodWeGotionGreener / Alfen
Growatt
HiteHithium
Huawei
Hypontech
Hyxipower
All In One ESSHybrid Inverters
Inverter DMEGCInverter ESYInverter PV, Ibridi e a Batteria AnklousiWellJinkoKacoKehuaKostal
Kstar
MarstekMastervoltMidTeQMotomaOctave EnergyOmniPowerPixiiPower-SonicPoweroadPylontechRegitecRenonRistrutturareRitarSAJSchneider SunEzySchucoSCUSE2200H fino a SE6000HSessySigenergySinexcel
Sma
Socomec
Sofar
Solaredge
SolarlogSolarMaxSolarwattSolaxSolinteg
Solis
Solplanet
Sungrow
SunwaytechSunwoda
Sunwoda
Sus-PowerTeclomanTeploreTesvoltVaconVictronVolstoraWattsNextWeihengXantrexZeversolar
Nuove integrazioni
Nuvola
Plc
Pompa di calore
Stazione di ricarica per veicoli elettrici
Inizio rapidoInstallazioneLED di statoLicenzaLinee guida per cablaggio e connettivitàRete
Risoluzione dei problemi
Segnali Esterni
Specifiche
Specifico per il cliente
Video tutoriali
DispositiviInverter ibridi Pv e per batterieHyxipower
logo

Dispositivi Supportati

Device TypeVariantsManualModbus TCP (Ethernet)RS485Curtailment
Inverter ibridoHYX-H5K-HTManual❌✅✅
HYX-H6K-HT
HYX-H8K-HT
HYX-H10K-HT
HYX-H12K-HT
HYX-H15K-HTManual
HYX-H20K-HT
HYX-H25K-HT

All In One ESS

Previous Page

Inverter DMEGC

Next Page

On this page

Dispositivi SupportatiCablaggioRS485

Cablaggio

RS485

Per il cablaggio RS485, utilizzare la porta di comunicazione riservata (N° 14) sull'inverter.

Info
RS485 Wiring
  • For correct RS485 wiring: Follow the guidelines for RS485 wiring.
  • If the wiring shown in the table below is incorrect, please let us know.
  • There is no general consensus in the industry about the usage of A and B for the RS485 polarity, so it may be counterintuitive and opposite of what you might expect for some devices.
DeviceSmartgridOne Controller model OM1SmartgridOne Controller model IG8RS485-USB converterRS485-Ethernet converter
RS485 A (Pin 5)RS485 ARS485_POSRS485 ATX+
RS485 B (Pin 6)RS485 BRS485_NEGRS485 BTX-
N/ARS GNDGNDNot availableG
Avviso
NOTE: RS485 Device Addresses
  • You MUST give each device on the RS485 bus a unique address. Check the manual of the device on how to do this.
  • Use lower addresses first (1, 2, ...) because the SmartgridOne Controller will find them faster!
  • For each device, it is generally recommended to stick with the factory default baud rate, parity, and stop bits. The SmartgridOne Controller will scan on those first.