SmartgridOne logo
SmartgridOne logo
Accessori
AppAvvertenze di sicurezza, manutenzione e legaliAvvio rapido
Cassetta degli attrezzi
Certificati
Configurazione dalla A alla Z
Controllore
Dispositivi
Caldaia
Carichi commutati
Cloud
Contatore del gas
Contatore dell'acqua
Contatore di Energia
Inverter Ibridi Fotovoltaici e per Batterie
a-TroniXABB, FIMERADS-TecAlphaESSAmpowrAngileApparecchiature EPAPsystems
Autarco
Batteria AtepsBeauventC-BatteryCellpowerChisageDanfossDeltaDEYEDiehl-AkoDynessDysun EnergyEcosourcenEenovanceElecnovaEnbrilionEnergreenEnerlutionEnjoyPowersEnphaseEVEFortona
Foxess
FraxFroniusGoodWeGotionGreener / Alfen
Growatt
HiteHithium
Huawei
Hypontech
Hyxipower
Inverter DMEGCInverter ESYInverter Fotovoltaici, Ibridi e a Batteria DET PowerInverter Fotovoltaici, Ibridi e per Batterie AnklousiWellJinkoKacoKehuaKostal
Kstar
MarstekMastervoltMidTeQMotomaOctave EnergyOmniPowerPixiiPower-SonicPoweroadPrimaPylontechRefurbRegitecRenonRitarSAJSchneider SunEzySchucoSCUSE2200H fino a SE6000HSessySigenergySinexcel
Sma
Socomec
Sofar
Solaredge
SolarlogSolarMaxSolarwattSolaxSolinteg
Solis
Solplanet
Sungrow
SunwaytechSunwoda
Sunwoda
Sus-PowerTeclomanTeploreTesvoltVaconVictronVolstoraWattsNextWeihengXantrexZendure SolarFlowZetaraZeversolar
Nuove integrazioni
Plc
Pompa di calore
Stazione di Ricarica EV
InstallazioneLED di statoLicenzaLinee guida per cablaggio e connettivitàRete
Risoluzione dei problemi
Segnali Esterni
Specifiche
Specifico del Cliente
Tempo di risposta del controlloVideo tutorial
DispositiviInverter Ibridi Fotovoltaici e per Batterie
logo

Inverter Dyness

Importante
Importante

Attualmente, l'integrazione supporta un limite di stato di carica fino al 95%. Questo perché quando lo stato di carica supera il 95%, la batteria può smettere di rispondere ai setpoint a causa delle azioni del sistema di gestione della batteria. Stiamo lavorando per risolvere questo problema con Dyness e altri partner.

Dispositivi Supportati

Device TypeVariantsModbus TCP (Ethernet)RS485Curtailment
EC100100kWh✅✅✅
DH100F71~100kWh
DH200F100kW/215kWh
DH200Y100kW/232kWh❌

Cablaggio

Il SmartgridOne Controller e gli inverter Dyness comunicano tramite RS485 o Ethernet.

Ethernet

Per un corretto cablaggio ethernet: Seguire .

RS485

Info
RS485 Wiring
  • For correct RS485 wiring: Follow the guidelines for RS485 wiring.
  • If the wiring shown in the table below is incorrect, please let us know.
  • There is no general consensus in the industry about the usage of A and B for the RS485 polarity, so it may be counterintuitive and opposite of what you might expect for some devices.
DeviceSmartgridOne Controller model OM1SmartgridOne Controller model IG8RS485-USB converterRS485-Ethernet converter
COM6 terminal 1ARS485 ARS485_POSRS485 ATX+
Com6 terminal 1BRS485 BRS485_NEGRS485 BTX-
N/ARS GNDGNDNot availableG
Dyness Wiring

Configurazione

DH100F

Il Dyness DH100F deve essere impostato in modalità remota:

  1. Cliccare sull'icona del menu principale nell'angolo in alto a destra dell'interfaccia principale
  2. Cliccare su "Data" nella barra del menu principale
  3. Cliccare su "EMS" nella barra del sottomenu
  4. Cliccare su "RunSet" in alto a sinistra della barra di navigazione
  5. Impostare la modalità di controllo su "Remoto"
Dyness DH100F Interface
Avviso
NOTE: RS485 Device Addresses
  • You MUST give each device on the RS485 bus a unique address. Check the manual of the device on how to do this.
  • Use lower addresses first (1, 2, ...) because the SmartgridOne Controller will find them faster!
  • For each device, it is generally recommended to stick with the factory default baud rate, parity, and stop bits. The SmartgridOne Controller will scan on those first.

Diehl-Ako

Previous Page

Dysun Energy

Next Page

On this page

Inverter DynessDispositivi SupportatiCablaggioEthernetRS485ConfigurazioneDH100F
le linee guida per il cablaggio ethernet