SmartgridOne logo
SmartgridOne logo
Accessori
AppAvvertenze di sicurezza, manutenzione e legaliAvvio rapido
Cassetta degli attrezzi
Certificati
Configurazione dalla A alla Z
Controllore
Dispositivi
Caldaia
Carichi commutati
Cloud
Contatore del gas
Contatore dell'acqua
Contatore di Energia
Inverter Ibridi Fotovoltaici e per Batterie
a-TroniXABB, FIMERADS-TecAlphaESSAmpowrAngileApparecchiature EPAPsystems
Autarco
Batteria AtepsBeauventC-BatteryCellpowerChisageDanfossDeltaDEYEDiehl-AkoDynessDysun EnergyEcosourcenEenovanceElecnovaEnbrilionEnergreenEnerlutionEnjoyPowersEnphaseEVEFortona
Foxess
FraxFroniusGoodWeGotionGreener / Alfen
Growatt
Serie Growatt MICSerie Growatt MIDSerie Growatt MINSerie Growatt MODSerie Growatt SPASerie Growatt SPHSerie Growatt UESerie Growatt WIT
HiteHithium
Huawei
Hypontech
Hyxipower
Inverter DMEGCInverter ESYInverter Fotovoltaici, Ibridi e a Batteria DET PowerInverter Fotovoltaici, Ibridi e per Batterie AnklousiWellJinkoKacoKehuaKostal
Kstar
MarstekMastervoltMidTeQMotomaOctave EnergyOmniPowerPixiiPower-SonicPoweroadPrimaPylontechRefurbRegitecRenonRitarSAJSchneider SunEzySchucoSCUSE2200H fino a SE6000HSessySigenergySinexcel
Sma
Socomec
Sofar
Solaredge
SolarlogSolarMaxSolarwattSolaxSolinteg
Solis
Solplanet
Sungrow
SunwaytechSunwoda
Sunwoda
Sus-PowerTeclomanTeploreTesvoltVaconVictronVolstoraWattsNextWeihengXantrexZendure SolarFlowZetaraZeversolar
Nuove integrazioni
Plc
Pompa di calore
Stazione di Ricarica EV
InstallazioneLED di statoLicenzaLinee guida per cablaggio e connettivitàRete
Risoluzione dei problemi
Segnali Esterni
Specifiche
Specifico del Cliente
Tempo di risposta del controlloVideo tutorial
DispositiviInverter Ibridi Fotovoltaici e per BatterieGrowatt
logo

Dispositivi Supportati

Device TypeManualModbus TCP (Ethernet)RS485Curtailment
MIN 2500-6000TL-XManual❌✅✅
MIN 2500-6000TL-XHManual
MIN 7000-10000TL-XManual
MIN 7000-10000TL-X2Manual

Cablaggio

Serie Growatt MID

Previous Page

Serie Growatt MOD

Next Page

On this page

Dispositivi SupportatiCablaggioRS485 - MIN 2500-6000TLRS485 - MIN 7000-10000TL

RS485 - MIN 2500-6000TL

Info
RS485 Wiring
  • For correct RS485 wiring: Follow the guidelines for RS485 wiring.
  • If the wiring shown in the table below is incorrect, please let us know.
  • There is no general consensus in the industry about the usage of A and B for the RS485 polarity, so it may be counterintuitive and opposite of what you might expect for some devices.
DeviceSmartgridOne Controller model OM1SmartgridOne Controller model IG8RS485-USB converterRS485-Ethernet converter
RS485 A1RS485 ARS485_POSRS485 ATX+
RS485 B1RS485 BRS485_NEGRS485 BTX-
N/ARS GNDGNDNot availableG
Image

RS485 - MIN 7000-10000TL

Info
RS485 Wiring
  • For correct RS485 wiring: Follow the guidelines for RS485 wiring.
  • If the wiring shown in the table below is incorrect, please let us know.
  • There is no general consensus in the industry about the usage of A and B for the RS485 polarity, so it may be counterintuitive and opposite of what you might expect for some devices.
DeviceSmartgridOne Controller model OM1SmartgridOne Controller model IG8RS485-USB converterRS485-Ethernet converter
RS485 A1RS485 ARS485_POSRS485 ATX+
RS485 B1RS485 BRS485_NEGRS485 BTX-
N/ARS GNDGNDNot availableG
Image
Image
Avviso
NOTE: RS485 Device Addresses
  • You MUST give each device on the RS485 bus a unique address. Check the manual of the device on how to do this.
  • Use lower addresses first (1, 2, ...) because the SmartgridOne Controller will find them faster!
  • For each device, it is generally recommended to stick with the factory default baud rate, parity, and stop bits. The SmartgridOne Controller will scan on those first.