SmartgridOne logo
SmartgridOne logo
AppCertifikaterController
Eksterne signaler
Enheder
Elbilopladningsstation
Energimåler
Gasmåler
Kedel
Nye integrationer
Plc
Pv Hybrid- og batteri-invertere
a-TroniXABB, FIMERADS-TecAlphaESSAlpvoltAmpowrAngileAnklous PV, Hybrid og Batteri InvertereAPsystemsAteps Batteri
Autarco
BattlinkBeauventC-BatteriCellpowerChisageDanfossDeltaDET Power PV, Hybrid og Batteri InvertereDEYEDiehl-AkoDMEGC InvertereDynessDysun EnergyEcosourcenEenovanceElecnovaEnbrilionEnergreenEnerlutionEnjoyPowersEnphaseEP UdstyrESY InvertereEVEFairlandFortonaForud for
Foxess
FraxFroniusGoodWeGotionGrønnere / Alfen
Growatt
HiteHithium
Huawei
Hypontech
Hyxipower
iWellJinkoKacoKehuaKostal
Kstar
KSTAR BluE-S Serien (Gen 1)KSTAR BlueSpark-serien (Gen 2)KSTAR C&I Hybrid Invertere
MarstekMastervoltMidTeQMotomaOctave EnergyOmniPowerPixiiPower-SonicPoweroadPylontechRCT PowerRegitecRenonRenoveringRitarSAJSchneider SunEzySchucoSCUSE2200H til SE6000HSessySigenergySinexcel
Sma
Socomec
Sofar
Solaredge
SolarlogSolarMaxSolarwattSolaxSolinteg
Solis
Solplanet
Sungrow
SunsynkSunwaytechSunwoda
Sunwoda
Sus-PowerTeclomanTeploreTesvoltVaconVictronVolstoraWattsNextWeihengXantrexZendure SolarFlowZetaraZeversolar
Sky
Vandmåler
Varmepumpe
Vekslende Belastninger
Fejlfinding
InstallationKom godt i gang
Konfiguration fra A til Z
Kontrol responstid
Kundespecifik
LicensNetværkRetningslinjer for ledningsføring og tilslutningSikkerhed, vedligeholdelse og juridiske meddelelserSpecifikationerStatus-LED'er
Tilbehør
Værktøjskasse
Videovejledninger
EnhederPv Hybrid- og batteri-invertereKstar
logo

KSTAR BlueSpark Serie (Gen 2)

Understøttede enheder

Device TypeVariantsModbus TCP (Ethernet)RS485CurtailmentMinimum device firmware version
BlueSpark (2. gen) EnkelfasetE(3.68/5/6)KS-D22❌✅✅ARM v1.3.00 eller nyere
BlueSpark (2. gen) TrefasetE(4/5/6/8/10/12)KT-D22Alle versioner
Advarsel
Advarsel

Den officielle KSTAR dokumentation bekræfter, at Modbus TCP (Ethernet) ikke understøttes til tredjepartskontrol på disse enheder. Vi anbefaler at forbinde KSTAR batteriet og Controller ved hjælp af RS485.

Kabler og tilslutning

SmartgridOne Controller og KSTAR inverterne kommunikerer via RS485.

Enkelfaset tilslutning (E..KS-D22)

Forbind Controller til CT/METER porten med et RS-485 kabel.

  • RS485-A: PIN 6
  • RS485-B: PIN 5
KSTAR connection diagram for single phase systems

Trefaset tilslutning (E..KT-D22)

Forbind Controller til METER/DRY porten (specifikt CT/METER pins).

  • RS485-A: PIN 6
  • RS485-B: PIN 5
KSTAR connection diagram for three-phase systems

Konfiguration

Advarsel
NOTE: RS485 Device Addresses
  • You MUST give each device on the RS485 bus a unique address. Check the manual of the device on how to do this.
  • Use lower addresses first (1, 2, ...) because the SmartgridOne Controller will find them faster!
  • For each device, it is generally recommended to stick with the factory default baud rate, parity, and stop bits. The SmartgridOne Controller will scan on those first.

For at sikre, at Controller kan kontrollere inverteren, skal følgende indstillinger konfigureres på inverteren via skærmen eller appen.

1. Arbejdsmodus indstillinger

For at VPP kontrol fungerer pålideligt, skal følgende indstillinger konfigureres:

  1. Sæt Work Mode til Self-Consumption.
  2. Sæt Charge from Grid til Disable (indenfor Self-Consumption menuen).

2. Deaktiver modstridende modes

Følgende modes har højere prioritet end fjernstyring og skal deaktiveres:

  • Force Charge/Discharge (Sæt til "Invalid" eller 0)
  • Generator Mode

3. Portkonfiguration

Sørg for, at kommunikationsporten er korrekt indstillet:

  • CT/Meter Valg: Sæt til CT (standard).
  • Baud Rate: 9600.
Note
Note

Genstart batteriinverteren efter ændring af indstillingerne.


Forsigtighed
Forsigtighed

Da batteriet går i sleep mode ved 10% SoC, anbefaler vi at sætte den mindste ladetilstand til mindst 12%. Når batteriet går i sleep mode, kan det ikke kontrolleres af SmartgridOne Controller.