| Device Type | Variants | Modbus TCP (Ethernet) | RS485 | Curtailment |
|---|---|---|---|---|
| Hybrid inverter | Dysun Hybrid | ✅ | ✅ | ❌ |
| FlexAmp | FlexAmp One 3.6K, FlexAmp One 5K | ❌ | ✅ |
Kabelføring
Modbus TCP
- Tilslut inverterens LAN-port til dit lokale netværk.
- Standardport: 502.
- Modbus enheds-ID skal sættes mellem 1–247 (standard 1).
RS485
Info
RS485 Wiring
- For correct RS485 wiring: Follow the guidelines for RS485 wiring.
- If the wiring shown in the table below is incorrect, please let us know.
- There is no general consensus in the industry about the usage of A and B for the RS485 polarity, so it may be counterintuitive and opposite of what you might expect for some devices.
| Device | SmartgridOne Controller model OM1 | SmartgridOne Controller model IG8 | RS485-USB converter | RS485-Ethernet converter |
|---|---|---|---|---|
| RS485-A | RS485 A | RS485_POS | RS485 A | TX+ |
| RS485-B | RS485 B | RS485_NEG | RS485 B | TX- |
| GND | RS GND | GND | Not available | G |
Serielle indstillinger:
- Baud rate: 9600 (standard) eller som konfigureret i inverterens menu
- Databit: 8
- Paritet: Ingen
- Stopbit: 1
Konfiguration
Advarsel
NOTE: RS485 Device Addresses
- You MUST give each device on the RS485 bus a unique address. Check the manual of the device on how to do this.
- Use lower addresses first (1, 2, ...) because the SmartgridOne Controller will find them faster!
- For each device, it is generally recommended to stick with the factory default baud rate, parity, and stop bits. The SmartgridOne Controller will scan on those first.
- Sæt Modbus-adressen (slave ID) mellem 1–247 i inverterens menu.
- Hver enhed på RS485-bussen skal have en unik adresse.
- For bedste praksis ved kabeltilslutning af RS485, se .
FlexAmp serieopsætning
Under enhedsscanning eller manuel konfiguration bliver du spurgt:
"Hvad er inkluderet i installationen?"
- Solpaneler og batteri (standard)
- Kun solpaneler
- Kun batteri
Vælg den mulighed, der matcher din installation for at sikre korrekt enhedsregistrering og overvågning.
Styring
Dysun Hybrid
Inverteren understøtter batteristyring:
- Ladetilstand: Indstil lade-strømmen i ampere
- Afladetilstand: Indstil afladeeffekten som procentdel
- Når styring er deaktiveret, går inverteren tilbage til autonom drift
Forsigtighed
Forsigtighed
Eksperimentel Styringsfunktioner for Dysun Hybrid er ikke valideret på levende hardware.