SmartgridOne logo
SmartgridOne logo
Acessórios
AplicativoAvisos de segurança, manutenção e legais
Caixa de Ferramentas
Certificados
Configuração de A a Z
ControladorDiretrizes para fiação e conectividade
Dispositivos
Bomba de Calor
Caldeira
Cargas Comutadas
Estação de Carregamento para Veículos Elétricos
Inversores Híbridos Fotovoltaicos e de Bateria
a-TroniXABB, FIMERADS-TecAforeAlphaESSAmpowrAngileAPsystems
Autarco
Bateria AtepsBateria-CBeauventCellpowerDanfossDeltaDEYEDiehl-AkoDynessDysun EnergyEcosourcenEenovanceElecnovaEnbrilionEnergreenEnerlutionEnjoyPowersEnphaseEquipamento EPEVEFortona
Foxess
FoxESS GMAXFoxESS Série HFoxESS Série R
FraxFroniusGoodWeGotionGravaçãoGreener / Alfen
Growatt
HiteHithium
Huawei
Hypontech
Hyxipower
Inversores DMEGCInversores ESYInversores Fotovoltaicos, Híbridos e de Bateria AnklousInversores Fotovoltaicos, Híbridos e de Bateria DET PoweriWellJinkoKacoKehuaKostal
Kstar
MarstekMastervoltMidTeQMotomaOctave EnergyOmniPowerPixiiPower-SonicPoweroadPylontechRCT PowerRecondicionamentoRegitecRenonRitarSAJSchneider SunEzySchucoSCUSE2200H até SE6000HSessySigenergySinexcel
Sma
Socomec
Sofar
Solaredge
SolarlogSolarMaxSolarwattSolaxSolinteg
Solis
Solplanet
Sungrow
SunwaytechSunwoda
Sunwoda
Sus-PowerTeclomanTeploreTesvoltVaconVictronVolstoraWattsNextWeihengXantrexZendure SolarFlowZetaraZeversolar
Medidor de Água
Medidor de Energia
Medidor de Gás
Novas integrações
Nuvem
Plc
Especificações
Específico para o Cliente
Início RápidoInstalaçãoLEDs de StatusLicençaRede
Resolução de Problemas
Sinais Externos
Tempo de resposta do controleTutoriais em vídeo
DispositivosInversores Híbridos Fotovoltaicos e de BateriaFoxess
logo

Dispositivos Suportados

Device TypeModbus TCP (Ethernet)RS485CurtailmentMinimum device firmware version
H3 (Não-Pro, Não-Smart): → ❗Veja a nota abaixo ❗❌✅❗(veja abaixo)Master: 2.05, Manager: 1.85 (*)
H3 AIO (All-In-One)✅❌Master: 1.33, Manager: 1.37 (*)
H3-Smart⌛ (em desenvolvimento)Master: 1.25, Manager: 1.14 (*)
H3-ProMaster: 1.62, Manager: 1.34 (*)
H1(experimental, requer testes)Master: 1.70, Manager: 1.78 (*)
H1-G2⌛ (em desenvolvimento)Master: 1.40, Manager: 1.54 (*)
P3-SH✅ (experimental)✅ (experimental)Master: 1.62, Manager: 1.34 (*)
Cuidado
Cuidado

H3 (Não-Pro, Não-Smart)

O H3 (Não-Pro, Não-Smart) tem protocolo de comunicação diferente dependendo da 'versão master' e 'versão manager' do inversor. Escolha a integração correspondente com base nas versões de software do inversor.

✅ Modulação de potência é suportada para versões de Firmware master v.2.05 e manager v.1.85 e inferiores.

⌛ Modulação de potência está em desenvolvimento para versões de Firmware master v.2.06 e manager v.1.86 e superiores.

Aviso
Aviso

A série H3 (não-pro, não-smart) utiliza um protocolo de comunicação diferente da série H3 Pro e H3 Smart. Portanto, ao selecionar o tipo de dispositivo no SmartgridOne Controller, você deve ter muita certeza de que está selecionando o tipo correto.

Nota
Nota

Versões de Firmware Suportadas

(*) A integração pode funcionar para versões de firmware mais antigas, mas estas não foram testadas.

Image 1

Cabeamento

Aviso
Aviso

O endereço padrão modbus, ou ID do dispositivo, é 247. Tenha isso em mente ao escanear um inversor. Você pode mudar os endereços mínimos e máximos do barramento que o controlador irá escanear nos parâmetros de escaneamento.

Ethernet

Para o cabeamento correto de ethernet: Siga as .

Aviso
Aviso

Você não pode conectá-lo através do dongle WiFi.

RS485

O inversor pode ser conectado ao SmartgridOne Controller via RS485. Isso é feito através da conexão [J] na imagem abaixo.

Info
RS485 Wiring
  • For correct RS485 wiring: Follow the guidelines for RS485 wiring.
  • If the wiring shown in the table below is incorrect, please let us know.
  • There is no general consensus in the industry about the usage of A and B for the RS485 polarity, so it may be counterintuitive and opposite of what you might expect for some devices.
DeviceSmartgridOne Controller model OM1SmartgridOne Controller model IG8RS485-USB converterRS485-Ethernet converter
Logger 485A / pin 1RS485 ARS485_POSRS485 ATX+
Logger 485B / pin 2RS485 BRS485_NEGRS485 BTX-
N/ARS GNDGNDNot availableG
Image 1

RS485 H3 Pro

Info
RS485 Wiring
  • For correct RS485 wiring: Follow the guidelines for RS485 wiring.
  • If the wiring shown in the table below is incorrect, please let us know.
  • There is no general consensus in the industry about the usage of A and B for the RS485 polarity, so it may be counterintuitive and opposite of what you might expect for some devices.
DeviceSmartgridOne Controller model OM1SmartgridOne Controller model IG8RS485-USB converterRS485-Ethernet converter
EMS 485A / pin 17RS485 ARS485_POSRS485 ATX+
EMS 485B / pin 18RS485 BRS485_NEGRS485 BTX-
N/ARS GNDGNDNot availableG
Image 1

Configuração para H3 (Não-Pro, Não-Smart) e H1-G2

1. Ativação do monitoramento e gestão do inversor

O controle deve ser ativado através do inversor, e o medidor deve ser desativado. Isso é feito através do display no menu Feature Parm. Primeiro, abra o menu Feature Parm conforme segue:

  1. Vá para o Menu.
Image 1
  1. Digite a senha. A padrão é 0000.
Image 1
  1. Selecione Configurações.
Image 1
  1. Selecione Feature Parm.

2. Ativando o controle remoto

Use o display na página Feature para ativar o controle, seguindo os passos abaixo:

  1. Selecione Controle Remoto.
Image 1
  1. Defina como Ativar.
Image 1

3. Desativando o medidor

O medidor deve ser desativado. O controle será assumido pelo SmartgridOne Controller. Portanto, o medidor não deve ser conectado ao inversor mas sim ao SmartgridOne Controller. Para desativar o medidor nas configurações, siga estes passos:

  1. Volte para a página Feature.
  2. Selecione Medidor1.
Image 1
  1. Selecione Configurar.
Image 1
  1. Defina como Desativar.
Image 1

4. Definindo o endereço do inversor

O endereço do inversor pode ser configurado também através do display.

  1. Vá ao menu Configurações como descrito anteriormente.
  2. Selecione Comunicação.
  3. Selecione RS485.
  4. Selecione ID do dispositivo.
  5. Defina o ID do dispositivo para o endereço desejado. Se você conectar múltiplos dispositivos no mesmo barramento RS485, deve atribuir um endereço único a cada um.
Image 1
Dica
Dica

Escaneamento mais rápido

O SmartgridOne Controller inicia o escaneamento a partir do endereço 1 por padrão. Escolher um endereço mais baixo fará com que seu inversor seja encontrado mais rápido.

Aviso
Aviso

Múltiplos inversores

Se você tiver múltiplos inversores, é importante definir endereços paralelos, cada inversor deve ter um endereço diferente.

Configuração para H3-smart e H3-Pro

O controle remoto está ativado por padrão, você não precisa alterar nenhuma configuração.

Alterar o endereço do inversor (ou ID do dispositivo) pode ser feito da mesma forma que para o H3 (veja acima).

FoxESS GMAX

Previous Page

FoxESS Série R

Next Page

On this page

Dispositivos SuportadosH3 (Não-Pro, Não-Smart)Versões de Firmware SuportadasCabeamentoEthernetRS485RS485 H3 ProConfiguração para H3 (Não-Pro, Não-Smart) e H1-G21. Ativação do monitoramento e gestão do inversor2. Ativando o controle remoto3. Desativando o medidor4. Definindo o endereço do inversorEscaneamento mais rápidoMúltiplos inversoresConfiguração para H3-smart e H3-Pro
diretrizes para cabeamento de ethernet