SmartgridOne logo
SmartgridOne logo
AppCertifikaterController
Eksterne Signaler
Enheder
Elbilopladningsstation
Energimåler
ABBAccuenergyAcrelAlgodueBilagBMR
Carlo Gavazzi
ChargeeChintCloud-målerdataDornscheidt
Eastron
Eniris
FluviusFroniusHagerHomeWizardHuaweiIneproIskra
Janitza
JoulzKaifaKamstrupKlar til SmartgridLandis+GyrLegrandLitiotM-BusMetcomP1ApiPhoenix-ContactPilotSagemcom
Schneider
ComPact NSXIEM 2100 SerieIEM 2100 SerienIEM 3000 SerienMasterPact MTZPM 800 SeriePM 3250PM 5000 SeriePM 8000PowerTag Energi
Self configured energy meterSeneca S604SessyShelly Energi målereSiemensSmappeeSocomecSolax
Solis
SunwodaTillquistVictronWeidmüllerYouLessZendure P1 MålerZiv
Gasmåler
Kedel
Nye integrationer
Plc
Pv Hybrid- og batteri-invertere
Sky
Vandmåler
Varmepumpe
Vekslende Belastninger
Fejlfinding
InstallationKom godt i gang
Konfiguration fra A til Z
Kontrolresponstid
Kundespecifik
LicensNetværkRetningslinjer for ledningsføring og tilslutningSikkerhed, vedligeholdelse og juridiske meddelelserSpecifikationerStatus-LED'er
Tilbehør
Værktøjskasse
Videovejledninger
EnhederEnergimålerSchneider

Schneider-Electric IEM 2100 Serien Energi Målere

logo

Understøttede enheder

IEM 2100 Serien er enfasede elmålere.

Device TypeModbus TCP (Ethernet)RS485
Schneider-Electric iEM 2100 Series❌✅
Schneider-Electric iEM 2150
Schneider-Electric iEM 2155
Schneider iEM 2150

Tilslutning

IEM 2100 serien kommunikerer via Modbus RTU over RS485.

Info
RS485 Wiring
  • For correct RS485 wiring: Follow the guidelines for RS485 wiring.
  • If the wiring shown in the table below is incorrect, please let us know.
  • There is no general consensus in the industry about the usage of A and B for the RS485 polarity, so it may be counterintuitive and opposite of what you might expect for some devices.
DeviceSmartgridOne Controller model OM1SmartgridOne Controller model IG8RS485-USB converterRS485-Ethernet converter
D1 (+)RS485 ARS485_POSRS485 ATX+
D0 (-)RS485 BRS485_NEGRS485 BTX-
0V / ShieldRS GNDGNDNot availableG

Se venligst i enhedens manual for præcise pin-placeringer, da disse kan variere en smule mellem specifikke undermodeller (f.eks. iEM2150 vs iEM2155).

Konfiguration

Advarsel
NOTE: RS485 Device Addresses
  • You MUST give each device on the RS485 bus a unique address. Check the manual of the device on how to do this.
  • Use lower addresses first (1, 2, ...) because the SmartgridOne Controller will find them faster!
  • For each device, it is generally recommended to stick with the factory default baud rate, parity, and stop bits. The SmartgridOne Controller will scan on those first.

Kommunikationsindstillinger

Sørg for, at enhedens indstillinger matcher driverens egenskaber som defineret nedenfor:

  • Baud Rate: 9600, 19200 eller 38400 (Standard er ofte 19200)
  • Parity: Jævn, Ulige eller Ingen
  • Stop Bits: 1
  • Data Bits: 8

Tjek enhedens manual for, hvordan du går ind i elmålerens konfigurationsmenu for at sætte Modbus-adressen og Baud Rate.

IEM 2100 Serie

Schneider-Electric IEM 2100 Serien Energimålere

IEM 3000 Serien

Schneider-Electric IEM 3000 serie energimålere

On this page

Understøttede enhederTilslutningKonfigurationKommunikationsindstillinger