IntegrationsBattery or PV invertersSolis integration

Local intervention

Connect to the COM port of the Solis inverter with a logger.

Solis Inverter
Note

If you are working with a LAN dongle or WiFi dongle, you can read the inverter via modbus TCP.

Connection Options

Data Logger Connection

Connect a data logger or smartgrid controller to enable monitoring and control capabilities.

Note

Please keep in hand your Data Loggers serial number. It should be starting for 7A to enable Modbus communication. If the S/N starts from 5A, the connection will not work.

Note

The current stable version of the Solis Data Loggers does not support Modbus Communication. In order to enable Modbus Communication, please contact Solis Support and ask Modbus TCP and Remote Dispatch to be enabled.

Smartgrid Controller

Connect via Modbus RTU to the COM port of the Solis inverter.

Solis Inverter

Solis API Monitoring

Previous Page

Sungrow integration

Next Page