Stödda enheter
| Device Type | Variants | Modbus TCP (Ethernet) | RS485 | Curtailment |
|---|---|---|---|---|
| Hybridinverter | Dysun Hybrid | ✅ | ✅ | ❌ |
| FlexAmp | FlexAmp One 3.6K, FlexAmp One 5K | ❌ | ✅ |
Kablar
Modbus TCP
- Anslut inverterens LAN-port till ditt lokala nätverk.
- Standardport: 502.
- Modbus enhets-ID måste vara inställt mellan 1–247 (standard 1).
RS485
Info
RS485 Wiring
- For correct RS485 wiring: Follow the guidelines for RS485 wiring.
- If the wiring shown in the table below is incorrect, please let us know.
- There is no general consensus in the industry about the usage of A and B for the RS485 polarity, so it may be counterintuitive and opposite of what you might expect for some devices.
| Device | SmartgridOne Controller model OM1 | SmartgridOne Controller model IG8 | RS485-USB converter | RS485-Ethernet converter |
|---|---|---|---|---|
| RS485-A | RS485 A | RS485_POS | RS485 A | TX+ |
| RS485-B | RS485 B | RS485_NEG | RS485 B | TX- |
| GND | RS GND | GND | Not available | G |
Seriella inställningar:
- Baudhastighet: 9600 (standard) eller enligt konfiguration i invertermenyn
- Databitar: 8
- Paritet: Ingen
- Stopbitar: 1
Konfiguration
Varning
NOTE: RS485 Device Addresses
- You MUST give each device on the RS485 bus a unique address. Check the manual of the device on how to do this.
- Use lower addresses first (1, 2, ...) because the SmartgridOne Controller will find them faster!
- For each device, it is generally recommended to stick with the factory default baud rate, parity, and stop bits. The SmartgridOne Controller will scan on those first.
- Ställ in Modbus-adressen (slave-ID) mellan 1–247 i invertermenyn.
- Varje enhet på RS485-bussen måste ha en unik adress.
- För bästa praxis vid RS485-kablage, se .
FlexAmp Series Setup
Vid enhetsskanning eller manuell konfiguration kommer du att bli tillfrågad:
"Vad ingår i installationen?"
- Solpaneler och batteri (standard)
- Endast solpaneler
- Endast batteri
Välj det alternativ som matchar din installation för att säkerställa korrekt enhetsdetektering och övervakning.
Styrning
Dysun Hybrid
Invertern stöder batteristyrning:
- Läggningsläge: Ställ in laddström i ampere
- Uttagsläge: Ställ in urladdningseffekt i procent
- När styrningen är avstängd återgår invertern till autonom drift
Försiktighet
Försiktighet
Experimentell Styrfunktioner för Dysun Hybrid har inte validerats på riktig hårdvara.