TODO: Det verkar som om detta gäller fler växelriktare?

Sofar TL-G3 och TLM/X-G3 Serien Växelriktare
Stödda Enheter
Device Type | Modbus TCP (Ethernet) | RS485 | Curtailment |
---|---|---|---|
... | ✅ | ✅ | ✅ |
warning
- De flesta av enheterna kan kommunicera via modbus TCP. Detta gäller inte för serien "SOFAR 1...40KTL"
- Vissa växelriktare kräver specifik firmware som är begränsad till vissa distributörer. Konsultera din distributör vid osäkerhet.
TODO: Slutför tabellen

Koppling
Ethernet
Anslut växelriktaren till ditt internet nätverk med "SOFAR SOLAR ETHERNET STICK LSE3".
För korrekt ethernetkoppling: Följ riktlinjerna för ethernetkoppling.
RS485
...TL-G3 & G1 & G2
RS485 Wiring
- For correct RS485 wiring: Follow the guidelines for RS485 wiring.
- If the wiring shown in the table below is incorrect, please let us know.
- There is no general consensus in the industry about the usage of A and B for the RS485 polarity, so it may be counterintuitive and opposite of what you might expect for some devices.
Device | SmartgridOne Controller model OM1 | SmartgridOne Controller model IG8 | RS485-USB converter | RS485-Ethernet converter |
---|---|---|---|---|
RS485s TX+ | RS485 A | RS485_POS | RS485 A | TX+ |
RS485s TX- | RS485 B | RS485_NEG | RS485 B | TX- |
N/A | RS GND | GND | Not available | G |

...TLX & TLM
RS485 Wiring
- For correct RS485 wiring: Follow the guidelines for RS485 wiring.
- If the wiring shown in the table below is incorrect, please let us know.
- There is no general consensus in the industry about the usage of A and B for the RS485 polarity, so it may be counterintuitive and opposite of what you might expect for some devices.
Device | SmartgridOne Controller model OM1 | SmartgridOne Controller model IG8 | RS485-USB converter | RS485-Ethernet converter |
---|---|---|---|---|
RS485s TX+ (pin 1) | RS485 A | RS485_POS | RS485 A | TX+ |
RS485s TX- (pin 3) | RS485 B | RS485_NEG | RS485 B | TX- |
N/A | RS GND | GND | Not available | G |

Konfiguration
RS485
NOTE: RS485 Device Addresses
- You MUST give each device on the RS485 bus a unique address. Check the manual of the device on how to do this.
- Use lower addresses first (1, 2, ...) because the SmartgridOne Controller will find them faster!
- For each device, it is generally recommended to stick with the factory default baud rate, parity, and stop bits. The SmartgridOne Controller will scan on those first.
Extern växelriktarkontroll måste aktiveras i konfigurationsmenyn för växelriktaren via LCD-skärmen.
- Klicka kort på knappen nedåt.
- Du kommer att se "1. Ange inställningar", håll knappen nedåt i 2 sekunder för att komma in i inställningarna.
- Gå igenom inställningarna tills du ser:
- Modbusadress eller
- Ställ in ComProtocol
- Håll knappen nedåt i 2 sekunder för att ställa in adressen.
- Ställ in adressen till det önskade värdet.