DEYE

Stödda enheter
Device Type | Variants | Modbus TCP (Ethernet) | RS485 | Curtailment |
---|---|---|---|---|
SG04LP3-EU | SUN-5/6/8/10/12K | ❌ | ✅ | ❌ |
SG01LP1-EU | SUN-12/14/16K |
Koppling
RS485
RS485 Wiring
- For correct RS485 wiring: Follow the guidelines for RS485 wiring.
- If the wiring shown in the table below is incorrect, please let us know.
- There is no general consensus in the industry about the usage of A and B for the RS485 polarity, so it may be counterintuitive and opposite of what you might expect for some devices.
Device | SmartgridOne Controller model OM1 | SmartgridOne Controller model IG8 | RS485-USB converter | RS485-Ethernet converter |
---|---|---|---|---|
Pin 1 / Modbus-485_B | RS485 A | RS485_POS | RS485 A | TX+ |
Pin 2 / Modbus-485_A | RS485 B | RS485_NEG | RS485 B | TX- |
Pin 3 / GND_485 | RS GND | GND | Not available | G |



Konfiguration
NOTE: RS485 Device Addresses
- You MUST give each device on the RS485 bus a unique address. Check the manual of the device on how to do this.
- Use lower addresses first (1, 2, ...) because the SmartgridOne Controller will find them faster!
- For each device, it is generally recommended to stick with the factory default baud rate, parity, and stop bits. The SmartgridOne Controller will scan on those first.
Gå till “Huvudsida” >> “Systeminställningar” >> “Avancerad funktion.”
- Modbus SN bör ställas in på ett nummer mellan 1 och 247. Välj inte 0!! Observera att om det finns flera enheter på RS485-bussen, bör varje ges ett unikt nummer. Detta är adressen.
- Slave ska vara markerad.
- Endast när en extra mätare är ansluten direkt till växelriktaren ska “EX_meter For CT” vara markerad. Om det endast finns en mätare parallellt med SmartgridOne Controller bör den vara avmarkerad.
- Se till att följande inställningar alla är korrekta: "Max A Laddning", "Max A Urladdning", "Nätets Laddningsampere"