Pular para o conteúdo principal
Ampowr

Inversores Ampowr

Dispositivos Suportados

Device TypeVariantsModbus TCP (Ethernet)RS485
AmpihomeMonofásico
Trifásico

Fiação

O SmartgridOne Controller e os inversores Ampihome se comunicam via RS485 ou Ethernet.

Ethernet

Para a fiação correta de ethernet: Siga as diretrizes para fiação de ethernet.

RS485

RS485 Wiring
  • For correct RS485 wiring: Follow the guidelines for RS485 wiring.
  • If the wiring shown in the table below is incorrect, please let us know.
  • There is no general consensus in the industry about the usage of A and B for the RS485 polarity, so it may be counterintuitive and opposite of what you might expect for some devices.
DeviceSmartgridOne Controller model OM1SmartgridOne Controller model IG8RS485-USB converterRS485-Ethernet converter
Pino 7 (Branco-Marron) RS485 ARS485_POSRS485 ATX+
Pino 8 (Marron) RS485 BRS485_NEGRS485 BTX-
N/A RS GNDGNDNot availableG
Fiação Monofásica Ampihome

Configuração

Ampihome Monofásico

O Ampihome Monofásico precisa ser configurado para Porta Secundária Escrava:

  1. Abra o aplicativo ESS Link
  2. Selecione "Meu" no canto inferior direito
  3. Selecione "Meu Dispositivo"
  4. Selecione o "Número de Comm." do dispositivo
  5. Selecione "Configurações de Parâmetro"
  6. Defina "Modo de Funcionamento" como "Modo de Carga Temporizada (C&D)"
  7. Selecione "Avançado" no canto superior direito
  8. Defina "Multiplexação RS485 BMS1" como "Porta Secundária Escrava"
Configurações Ampihome 1
Configurações Ampihome 2
NOTE: RS485 Device Addresses
  • You MUST give each device on the RS485 bus a unique address. Check the manual of the device on how to do this.
  • Use lower addresses first (1, 2, ...) because the SmartgridOne Controller will find them faster!
  • For each device, it is generally recommended to stick with the factory default baud rate, parity, and stop bits. The SmartgridOne Controller will scan on those first.