Power-Sonic

Obsługiwane urządzenia
Device Type | Modbus TCP (Ethernet) | RS485 | Curtailment |
---|---|---|---|
... | ❌ | ✅ | ❌ |
TODO: Uzupełnij tabelę
Okablowanie
RS485
RS485 Wiring
- For correct RS485 wiring: Follow the guidelines for RS485 wiring.
- If the wiring shown in the table below is incorrect, please let us know.
- There is no general consensus in the industry about the usage of A and B for the RS485 polarity, so it may be counterintuitive and opposite of what you might expect for some devices.
Device | SmartgridOne Controller model OM1 | SmartgridOne Controller model IG8 | RS485-USB converter | RS485-Ethernet converter |
---|---|---|---|---|
RS485 A | RS485_POS | RS485 A | TX+ | |
RS485 B | RS485_NEG | RS485 B | TX- | |
RS GND | GND | Not available | G |

TODO: Uzupełnij piny kabla w tabeli.
Konfiguracja
NOTE: RS485 Device Addresses
- You MUST give each device on the RS485 bus a unique address. Check the manual of the device on how to do this.
- Use lower addresses first (1, 2, ...) because the SmartgridOne Controller will find them faster!
- For each device, it is generally recommended to stick with the factory default baud rate, parity, and stop bits. The SmartgridOne Controller will scan on those first.
- Ustaw tryb pracy na Samo Zużycie

- Ustaw Zero Export na Wyłącz

- Ustaw Zdalne Sterowanie na Włącz

- Ustaw adres RS485. Domyślna prędkość transmisji to 9600, jeśli nie, ustaw na 9600.

- Ustaw prąd ładowania. Ustaw prąd ładowania.
WAŻNE!
Dla 5KT ustaw na 100 Dla 10KT ustaw na 160

- Ustaw AC Couple na Włącz