Autel charging stations
Supported Devices
| Device Type | Variants | Modbus TCP (Ethernet) | RS485 |
|---|---|---|---|
| MaxiCharger DC Compact | 40 kW | ✅ | ✅ |
| MaxiCharger DC Fast | 40–240 kW | ||
| MaxiCharger AC Ultra | 2 × 22 kW | ❌ |

Wiring
Ethernet
For correct Ethernet wiring, follow the guidelines for Ethernet wiring.
RS485
RS485 Wiring
- For correct RS485 wiring: Follow the guidelines for RS485 wiring.
- If the wiring shown in the table below is incorrect, please let us know.
- There is no general consensus in the industry about the usage of A and B for the RS485 polarity, so it may be counterintuitive and opposite of what you might expect for some devices.
| Device | SmartgridOne Controller model OM1 | SmartgridOne Controller model IG8 | RS485-USB converter | RS485-Ethernet converter |
|---|---|---|---|---|
| RS485 A | RS485_POS | RS485 A | TX+ | |
| RS485 B | RS485_NEG | RS485 B | TX- | |
| RS GND | GND | Not available | G |
Configuration
After the electrical installation of a charger is complete, follow these steps to configure communication with the SmartgridOne Controller.