Ampowr Omvormers
Ondersteunde Apparaten
Device Type | Variants | Modbus TCP (Ethernet) | RS485 |
---|---|---|---|
Ampihome | Eén-fase | ❌ | ✅ |
Drie-fase | ❌ |
Bekabeling
De SmartgridOne Controller en de Ampihone omvormers communiceren via RS485 of Ethernet.
Ethernet
Voor correcte ethernet bekabeling: Volg de richtlijnen voor ethernet bekabeling.
RS485
RS485 Wiring
- For correct RS485 wiring: Follow the guidelines for RS485 wiring.
- If the wiring shown in the table below is incorrect, please let us know.
- There is no general consensus in the industry about the usage of A and B for the RS485 polarity, so it may be counterintuitive and opposite of what you might expect for some devices.
Device | SmartgridOne Controller model OM1 | SmartgridOne Controller model IG8 | RS485-USB converter | RS485-Ethernet converter |
---|---|---|---|---|
Pin 7 (Wit-Bruin) | RS485 A | RS485_POS | RS485 A | TX+ |
Pin 8 (Bruin) | RS485 B | RS485_NEG | RS485 B | TX- |
N/B | RS GND | GND | Not available | G |

Configuratie
Ampihome Eén-Fase
De Ampihome Eén-Fase moet ingesteld worden op Slave Secondary Port:
- Open de ESS Link app
- Selecteer "Mijn" in de rechterbenedenhoek
- Selecteer "Mijn Apparaat"
- Selecteer "Comm No." van het apparaat
- Selecteer "Parameter Instellingen"
- Stel "Werkomvang" in op "Tijdgestuurde Oplaadmodus (C&D)"
- Selecteer "Geavanceerd" in de rechterbovenhoek
- Stel "BMS1 RS485 Multiplexing" in op "Slave Secondary Port"


NOTE: RS485 Device Addresses
- You MUST give each device on the RS485 bus a unique address. Check the manual of the device on how to do this.
- Use lower addresses first (1, 2, ...) because the SmartgridOne Controller will find them faster!
- For each device, it is generally recommended to stick with the factory default baud rate, parity, and stop bits. The SmartgridOne Controller will scan on those first.