DEYE

logo

समर्थित उपकरण

Device TypeVariantsModbus TCP (Ethernet)RS485Curtailment
SG04LP3-EUSUN-5/6/8/10/12K
SG01LP1-EUSUN-12/14/16K

वायरिंग

RS485

RS485 Wiring
  • For correct RS485 wiring: Follow the guidelines for RS485 wiring.
  • If the wiring shown in the table below is incorrect, please let us know.
  • There is no general consensus in the industry about the usage of A and B for the RS485 polarity, so it may be counterintuitive and opposite of what you might expect for some devices.
DeviceSmartgridOne Controller model OM1SmartgridOne Controller model IG8RS485-USB converterRS485-Ethernet converter
Pin 1 / Modbus-485_B RS485 ARS485_POSRS485 ATX+
Pin 2 / Modbus-485_A RS485 BRS485_NEGRS485 BTX-
Pin 3 / GND_485 RS GNDGNDNot availableG
Image 1
Image 1
Image 1

कॉन्फ़िगरेशन

NOTE: RS485 Device Addresses
  • You MUST give each device on the RS485 bus a unique address. Check the manual of the device on how to do this.
  • Use lower addresses first (1, 2, ...) because the SmartgridOne Controller will find them faster!
  • For each device, it is generally recommended to stick with the factory default baud rate, parity, and stop bits. The SmartgridOne Controller will scan on those first.

“मुख्य स्क्रीन” >> “सिस्टम सेटिंग्स” >> “उन्नत फ़ंक्शन” पर जाएं।

  • Modbus SN को 1 और 247 के बीच किसी भी संख्या पर सेट किया जाना चाहिए। 0 का चयन न करें!! ध्यान दें कि यदि RS485 बस पर कई उपकरण हैं, तो प्रत्येक को एक अनूठी संख्या दी जानी चाहिए। यह पता है।
  • स्लेव को चेक किया जाना चाहिए।
  • केवल तब “EX_meter For CT” को चेक किया जाना चाहिए जब एक अतिरिक्त मीटर सीधे इन्वर्टर से जुड़ा हो। यदि SmartgridOne Controller के साथ केवल एक मीटर समानांतर में है, तो इसे अनचेक किया जाना चाहिए।
  • सुनिश्चित करें कि निम्नलिखित सेटिंग्स सभी सही हैं: "Max A Charge", "Max A Discharge", "Grid Charge Ampere"
Image 1