ESY Residential Hybrid Inverters

Supported Devices

Device TypeVariantsModbus TCP (Ethernet)RS485Curtailment
Sunhome Hybrid Inverter (single phase)HM6

Wiring

The SmartgridOne Controller and the ESY inverters communicate via RS485.

Configuration

attention

Inverters with firmware version older than the following have a minimum SoC level of 35%. Starting from this version, this setting can be configured by the user.

Minimum required version: MCU version 1040, DSP version 1042.

NOTE: RS485 Device Addresses
  • You MUST give each device on the RS485 bus a unique address. Check the manual of the device on how to do this.
  • Use lower addresses first (1, 2, ...) because the SmartgridOne Controller will find them faster!
  • For each device, it is generally recommended to stick with the factory default baud rate, parity, and stop bits. The SmartgridOne Controller will scan on those first.