Aller au contenu principal
Ampowr

Onduleurs Ampowr

Appareils pris en charge

Device TypeVariantsModbus TCP (Ethernet)RS485
AmpihomeMonophasé
Triphasé

Câblage

Le SmartgridOne Controller et les onduleurs Ampihone communiquent via RS485 ou Ethernet.

Ethernet

Pour un câblage Ethernet correct : Suivez les directives pour le câblage Ethernet.

RS485

RS485 Wiring
  • For correct RS485 wiring: Follow the guidelines for RS485 wiring.
  • If the wiring shown in the table below is incorrect, please let us know.
  • There is no general consensus in the industry about the usage of A and B for the RS485 polarity, so it may be counterintuitive and opposite of what you might expect for some devices.
DeviceSmartgridOne Controller model OM1SmartgridOne Controller model IG8RS485-USB converterRS485-Ethernet converter
Pin 7 (Blanc-Marron) RS485 ARS485_POSRS485 ATX+
Pin 8 (Marron) RS485 BRS485_NEGRS485 BTX-
N/A RS GNDGNDNot availableG
Câblage Monophasé Ampihome

Configuration

Ampihome Monophasé

L'Ampihome Monophasé doit être configuré sur le Port Secondaire Esclave :

  1. Ouvrez l'application ESS Link
  2. Sélectionnez "Mon" dans le coin inférieur droit
  3. Sélectionnez "Mon Appareil"
  4. Sélectionnez le "N° Comm." de l'appareil
  5. Sélectionnez "Paramètres des Paramètres"
  6. Réglez "Mode de Fonctionnement" sur "Mode de Charge Programmée (C&D)"
  7. Sélectionnez "Avancé" dans le coin supérieur droit
  8. Réglez "Multiplexage BMS1 RS485" sur "Port Secondaire Esclave"
Paramètres Ampihome 1
Paramètres Ampihome 2
NOTE: RS485 Device Addresses
  • You MUST give each device on the RS485 bus a unique address. Check the manual of the device on how to do this.
  • Use lower addresses first (1, 2, ...) because the SmartgridOne Controller will find them faster!
  • For each device, it is generally recommended to stick with the factory default baud rate, parity, and stop bits. The SmartgridOne Controller will scan on those first.