Saltar al contenido principal
Ampowr

Inversores Ampowr

Dispositivos Soportados

Device TypeVariantsModbus TCP (Ethernet)RS485
AmpihomeMonofásico
Trifásico

Cableado

El SmartgridOne Controller y los inversores Ampihone se comunican a través de RS485 o Ethernet.

Ethernet

Para un cableado correcto de ethernet: Siga las directrices para el cableado de ethernet.

RS485

RS485 Wiring
  • For correct RS485 wiring: Follow the guidelines for RS485 wiring.
  • If the wiring shown in the table below is incorrect, please let us know.
  • There is no general consensus in the industry about the usage of A and B for the RS485 polarity, so it may be counterintuitive and opposite of what you might expect for some devices.
DeviceSmartgridOne Controller model OM1SmartgridOne Controller model IG8RS485-USB converterRS485-Ethernet converter
Pin 7 (Blanco-Marrón) RS485 ARS485_POSRS485 ATX+
Pin 8 (Marrón) RS485 BRS485_NEGRS485 BTX-
N/A RS GNDGNDNot availableG
Cableado Monofásico de Ampihome

Configuración

Ampihome Monofásico

El Ampihome Monofásico necesita ser configurado en el Puerto Secundario Esclavo:

  1. Abra la aplicación ESS Link
  2. Seleccione "Mi" en la esquina inferior derecha
  3. Seleccione "Mi Dispositivo"
  4. Seleccione el "Núm. de Comm." del dispositivo
  5. Seleccione "Configuraciones de Parámetro"
  6. Configure "Modo de Trabajo" a "Modo de Carga Temporal (C&D)"
  7. Seleccione "Avanzado" en la esquina superior derecha
  8. Configure "Multiplexión BMS1 RS485" a "Puerto Secundario Esclavo"
Configuraciones de Ampihome 1
Configuraciones de Ampihome 2
NOTE: RS485 Device Addresses
  • You MUST give each device on the RS485 bus a unique address. Check the manual of the device on how to do this.
  • Use lower addresses first (1, 2, ...) because the SmartgridOne Controller will find them faster!
  • For each device, it is generally recommended to stick with the factory default baud rate, parity, and stop bits. The SmartgridOne Controller will scan on those first.